Other liquid samples, Serum, Cell culture supernatants, Plasma, Cell lysate
Assay Type
Sandwich
Recovery
Matrices listed below were spiked with certain level of Ste2 and the recovery rates were calculated by comparing the measured value to the expected amount of Ste2 in samples.
Matrix
Recovery range(%)
Average(%)
serum(n=5)
85-101
92
EDTA plasma(n=5)
86-101
92
heparin plasma(n=5)
88-98
93
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Ste2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Ste2 ELISA Kit allows for the in vitro quantitative determination of Ste2 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Precision
Intra-Assay: CV<8% Inter-Assay: CV<10%
Storage
2-8 °C for 6 months