Matrices listed below were spiked with certain level of SELP and the recovery rates were calculated by comparing the measured value to the expected amount of SELP in samples.
Matrix
Recovery range(%)
Average(%)
serum(n=5)
85-100
93
EDTA plasma(n=5)
87-105
99
heparin plasma(n=5)
85-104
94
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of SELP and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
SELP(P-Selectin)/CD62P/GMP140/GRMP/PADGEM/PSEL/CD62P antigen/antigen CD62/selectin P
Notes
For Research Use Only
UniProt ID
Q28657
Antigen
SELP
Applications
ELISA
Applications Notes
SELP ELISA Kit allows for the in vitro quantitative determination of SELP concentrations in serum, plasma, tissue homogenates and other biological fluids.