Matrices listed below were spiked with certain level of Eapa2 and the recovery rates were calculated by comparing the measured value to the expected amount of Eapa2 in samples.
Matrix
Recovery range(%)
Average(%)
serum(n=5)
89-95
92
EDTA plasma(n=5)
87-97
92
heparin plasma(n=5)
85-99
91
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Eapa2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Eapa2 ELISA Kit allows for the in vitro quantitative determination of Eapa2 concentrations in serum, plasma, tissue homogenates and other biological fluids.
Precision
Intra-Assay: CV<8% Inter-Assay: CV<10%
Storage
2-8 °C for 6 months