Matrices listed below were spiked with certain level of AQP-2 and the recovery rates were calculated by comparing the measured value to the expected amount of AQP-2 in samples.
Matrix
Recovery range(%)
Average(%)
serum(n=5)
88-103
95
EDTA plasma(n=5)
89-104
96
heparin plasma(n=5)
85-105
94
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of AQP-2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
AQP-2/Aquaporin-2(AQP-2)/Water channel protein for renal collecting duct/WCH-CD/Collecting duct water channel protein/ADH water channel/Aquaporin-CD(AQP-CD)
Notes
For Research Use Only
UniProt ID
P56402
Antigen
AQP-2
Applications
ELISA
Applications Notes
AQP-2 ELISA Kit allows for the in vitro quantitative determination of AQP-2 concentrations in serum, plasma, tissue homogenates and other biological fluids.