Use 20 uL samples. Linear detection range: colorimetric assay 6 to 1000 uM, fluorimetric assay 1 to 100 uM ascorbic acid.
Intended Use
OD570nm,or FL530/585nm
Detection Principle
OD, FL: 6, 1 uM
Shelf Life
6 months
Specifity
For quantitative determination of ascorbate (ascorbic acid) and evaluation of drug effects on ascorbic acid metabolism.
Reference
Susanto, L., Y. Siregar, and L. Kusumawati (2018). Vitamin C supplementation improve the sputum conversion culture rate in pulmonary tuberculosis treatment while rifampicin susceptible. IOP Conference Series: Earth and Environmental Science 125(1). Assay: Ascorbic acid in human plasma.
Kantar, Michael B., et al (2016). Vitamin variation in Capsicum Spp. provides opportunities to improve nutritional value of human diets. PloS one 11.8: e0161464. Assay: Ascorbic acid in pepper tissue.
Trezzi, Jean-Pierre, et al (2016). LacaScore: a novel plasma sample quality control tool based on ascorbic acid and lactic acid levels. Metabolomics 12.6: 96. Assay: Ascorbic acid in human plasma.
Sasaki, M. et al (2012). D-2-hydroxyglutarate produced by mutant IDH1 perturbs collagen maturation and basement membrane function. Genes & Dev. 26: 2038-2049. Assay: Ascorbic acid in mouse cell.
Ching-Shih Chen et al (2011). Thiazolidinedione Energy Restriction-Mimetic Agents. US 2011/0086895 Al. Assay: Ascorbic acid in mouse cell.
To find more recent publications, please click here.